DHI Water Transfer PHA Builder

Purpose-built for temporary water transfer: source → screened suction → primary/backup pumping → transfer line → intermediate pumps/valves/heat manifolds/road crossings → final meter → receiving storage. The questionnaire creates only the applicable PHA nodes and startup checks.

Operating philosophy: Keep the PHA focused on flow, pressure, containment, routing, monitoring, remote control, freezing/heat introduction, and source/destination capacity. This tool is not intended for chemical treatment, process vessels, H₂S process design, or unrelated PSM topics.

Saved PHA Library

Every saved PHA is stored in this browser and can be searched or filtered by customer and job name.
Job NameCustomer / SitePHA DateOps LeadRowsHigh/CritLast SavedActions

1. Job Information

2. Water Transfer Setup — Brief Questionnaire

Answer these questions. The PHA nodes and questions below will be created automatically.

A. Source

B. Primary Pump Station

C. Transfer Route

D. Destination

E. Operating Limits

3. Generated Transfer Configuration

4. Water Transfer PHA

Only questions applicable to the configured transfer system are generated. Fill in safeguards and actions only where the existing arrangement is not adequate.
NodeDeviation / HazardPHA QuestionTypical CausesPotential ConsequencesExisting / Required SafeguardsSLRiskAction / RecommendationOwnerStatus

5. PSSR / Pre-Startup Verification

#CategoryVerificationRequired Before StartOwnerStatus

6. Sign-Off